Magnetic flux leakage (MFL) is a magnetic method of non-destructive testing that is used to detect corrosion, pitting and wall loss in steel structures.
MFL provides a cost-effective and high-speed inspection of tank floors. Our qualified MFL inspectors are backed by years of experience and have screened over 125 tank floors. We use MFL equipment such as Floormap VS2i and Floormap 3D.
The method uses permanent or electromagnets to magnetise the tank floor and the resulting magnetic field changes are recorded and analysed. If there is corrosion, pitting or wall loss, the magnetic field ‘leaks’ and the ‘leakage’ is analysed to determine the location and severity of the defect of the tank floor – both near and far surface.
A map of the corroded areas is provided with the MFL method and this essential data can be stored for future reference and planning.
Intertek is committed to ensuring our non-destructive testing inspections meet deadlines as we appreciate the importance of maintenance/outage schedules for industries such as petrochemical. By partnering with Intertek, you have the Total Quality Assurance of our in-depth expertise and the confidence that your maintenance/outage schedules will be met.