Effective January 1, 2017
Effective Date (see Schedule below): January 1, 2017
Impact Statement: A review of all Listing Reports is necessary to determine which products comply with new/revised requirements and which products will require re-evaluation. NOTE: Effective immediately, this revised standard will be exclusively used for evaluation of new products unless the Applicant requests in writing that current requirements be used along with their understanding that their listings will be withdrawn on Effective Date noted above, unless the product is found to comply with new/revised requirements.
Overview of Changes: Major changes include: 1. Addition of requirements allowing smaller gauge conductors; 2. Addition of provisions for low-voltage limited-energy products; 3. Addition of requirements for integral overcurrent protection of decorative lighting products; 4. Addition of requirements for products designated for commercial use; 5. Updated product markings; 6. Incorporation of requirements for flexible light cable systems (Rope Lights), previously in T.I.L. B-39; and 7. Incorporation of requirements from T.I.L. B-70. Specific details of new/revised requirements are found in table below.
Client Action Required:
Information – To assist our Engineer with review of your Listing Reports, please submit technical information in response to the new/revised paragraphs noted in the attached or explain why these new/revised requirements do not apply to your product(s).
Current Listings Not Active? – Please immediately identify any current Listing Reports or products that are no longer active and should be removed from our records. We will do this at no charge as long as Intertek is notified in writing prior to the review of your reports.
NOTE: Additions to existing requirements are underlined and deletions are shown lined out below.
Clause | Verdict | Comment |
---|---|---|
1 | NA | Scope: Updated to include ornaments, decorative outfits, controllers and flashers, and accessories. Strings employing lampholders larger than intermediate-screw are not within the scope of this standard. |
2 | NA | Reference publications Updated with current and active standards. |
5 | NA | General requirements General mechanical and electrical construction requirements for all decorative lighting products are in Clauses 5.1 & 5.2. |
5.1 | Mechanical construction Update of mechanical construction requirements which include:
| |
5.2 | Electrical construction Update of electrical construction requirements which include:
| |
5.3 | Outdoor locations Update of requirements for outdoor use products. | |
5.4 | Commercial use product Addition of requirements for commercial use products. | |
5.5 | Motorized devices Updated requirements. | |
5.6 | Direct plug-in units—Supplementary requirements Addition of requirements for Direct Plug-in power supplies. | |
5.7 | Products with battery chargers Additional requirements for products with Battery Chargers. | |
5.8 | Tests for all products excluding ornaments and rope lighting systems
| |
5.9 | Additional tests for products with polymeric enclosures Test requirements for products with polymeric enclosures. | |
5.10 | Tests for products employing overcurrent protective devices New test requirements for products with an overcurrent protective device (fuse and fuse holder). | |
5.11 | Additional tests for wiring devices Test requirements for wiring devices | |
5.12 | Additional tests for products intended for outdoor locations Test requirements for outdoor products | |
5.13 | Additional tests for direct plug-in units Test requirements for products employing a direct plug-in power supply. | |
5.15 | Manufacturing and production test Addition of manufacturing and production line tests. | |
5.17 | Markings Marking requirements have been updated for cautions and warnings included on the product, tags, and packaging. | |
5.18 | Installation manual Requirements for contents of an installation manual have been revised and updated. | |
6 | Decorative Lighting Strings Requirements specific to series and parallel connected lighting strings. | |
6.1 | Lampholders Updated requirements for lampholders. Medium base and larger screw-base lampholders are no longer permitted for products in this standard. | |
6.2 | Series-connected lampholders Requirements for series-connected lampholders updated to cover screw-base and push-in types, and for non-replaceable lamps. | |
6.3 | Series-connected strings—Supplementary requirements Requirements for series-connected lighting strings updated with minimum number of lampholders per string, maximum current ratings, and restriction on number of individual-flashing lamps per string. | |
6.4 | Parallel-connected strings – Supplementary requirements Requirements for parallel-connected lighting strings updated with a minimum number of lampholders per string, max watts per lamp, and inclusion of only intermediate or candelabra screw-base lampholders. | |
6.5 | Additional tests for products with series-connected lampholders New requirements added for lampholders. Tests for conductor connection and contact security have been updated. Added requirements for a strengthening member. | |
6.6 | Additional tests for decorative lighting strings Requirements added for decorative lighting strings testing. | |
7 | Decorative lighting outfits (silhouettes) Updated requirements applicable to decorative lighting outfits such as silhouettes, light sculptures, motorized figures, and ornaments. | |
8 | Artificial trees and tree stands Supplementary requirements for artificial trees (i.e., pre-lit trees) and tree stands. | |
Annex A | Lamps for decorative lighting products(Normative) Specific requirements for lamps provided with decorative lighting products. | |
Annex B | Lamps for decorative lighting products(Normative) Specific requirements for lamps provided with decorative lighting products. | |
Annex C | Printed circuit boards (PCB) (Normative) Specific construction and test requirements for printed circuit boards employed in decorative lighting products. | |
Annex D | Flexible light cable systems (rope lights) (Normative) Incorporation of construction and test requirements for flexible light cable systems (rope lights) from TIL CSA B-39. |
CUSTOMERS PLEASE NOTE: This Table and column "Verdict" can be used in determining how your current or future production is or will be in compliance with new/revised requirements.